Page 151 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 151

DRAFT                                                            135-1. BUilDiNG tYPeS

                                                                                           House C Building Type



                                            N3b, N3c         N4              NX1                NOTeS/ReFeReNCeS
           B.  Height. Refer to Figure 1.15-C
           1@  Minimum Overall Height       1 story          1.5 story       1.5 story
                                                                                                See 135-7.1.7 for
           1#  Maximum Overall Height       2 stories        2 stories       2 stories          measurement information.
                                                                                                Story heights are measured
                                                                                                floor to floor.
               All Full Stories: (Measured floor-to-floor)
           1$    Minimum Height (ft)        8.5              8.5             8.5
                 Maximum Height (ft)        10               10              10
           c.  Uses. Refer to Figure 1.15-C.
                                                                                                See Chapter 134, Article 3 for
                                                                                                permitted uses per zoning
           1%  All Stories                  Any permitted use;                                  district and definition of uses.
                                            N3b-2 and N3c-2 districts allow up to 2 units
                                                                                                See Note 3 for 2- unit
                                                                                                configuration requirements.
           1^  Required Occupied Space      Minimum 20-foot depth on all full floors except basement on front facade  See 135-7.2 for definition of
                                                                                                occupied space.
               Parking within Principal                                                         Refer to occupied space
           1& Building                      Fully in any basement or in the rear of the ground story  requirement above.
           D. Street Facade & roof requirements. Refer to Figure 1.15-D
               Minimum Transparency         12%; blank wall   18%; blank wall                   See 135-7.1.7 for
           1*  per each Full Story & any Visible  limitations apply to   limitations apply to   15%; blank wall limitations  measurement information
                                                                                                and definition of blank wall
                                                                             apply to street facades
               Basement                     front facade     front facade                       limitations.
               Principal Entrance Number    minimum one per building                            See Note 2 and Note 3 for 2-
           1( Principal Entrance Location   front street facade                                 and 4-unit building entrance
                                                                                                requirements.
               Required Entrance                                                                See 135-7.2 for definition of
           2) Configuration                 stoop or porch                                      stoop and porch.
               Specific Permitted Major     finished wood, brick,            finished wood, brick,   See 135-2.2 for facade and
           2! Building Materials            stone, fiber cement   brick or stone  stone, fiber cement board roof materials
                                            board
                                            pitched gable roof for 1 and 1.5 stories;
           2@  Permitted Roof Types         low pitched roof for 2 stories;                     See 135-1.17 for roof types
                                            other roof types permitted with a type 1 design exception per 135-6.2
                                            On 1 and 1.5 story buildings, where the ridge line is parallel to the street, at
           2#  Dormers & Gables             least one dormer or gable end is required for every 24 feet of continuous   See 135-7.2 for definition of
                                                                                                dormer.
                                            ridgeline.
               Street Facade Horizontal Eaves   1 story: maximum 8.5                            Measured from top of
           2$ Height (ft)                   1.5 to 2 story: maximum 16                          foundation to below eave




                           1^




                                                                  2@               2#
                           1$ 1%
              1@                                                                                     2!
              1#                                                   2$                          typical  1*
                           1$ 1%           1&


                                  1&       1&
                                                                                 1(2)



          Figure 1.15-C. House C Building: Height & use Requirements  Figure 1.15-D. House C Building: Facade Requirements