Page 147 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 147

DRAFT                                                            135-1. BUilDiNG tYPeS

                                                                                           House B Building Type



                                            N3a, N3b                                NOTeS/ReFeReNCeS
           B.  Height. Refer to Figure 1.14-C
           1@  Minimum Overall Height       1 story
           1#  Maximum Overall Height       2 stories                               See 135-7.1.7 for measurement information.
                                                                                    Story heights are measured floor to floor.
               All Stories: (Measured floor-to-floor)
           1$    Minimum Height (ft)        7
                 Maximum Height (ft)        9
           c.  Uses. Refer to Figure 1.14-C
                                                                                    See Chapter 134, Article 3 for permitted uses
           1%  All Stories                  Any permitted use;                      per zoning district and definition of uses.
                                                                                    See Note 2 for 2- unit configuration
                                            N3a-2 and N3b-2 allows up to 2 units
                                                                                    requirements.
           1^  Required Occupied Space      minimum 20-foot depth on all full floors on at least 60%   See 135-7.2 for definition of occupied space.
                                            of front facade
               Parking within Principal
           1& Building                      maximum 50% of basement; maximum 30% of first floor  Refer to occupied space requirement above.
           D. Street Facade & roof requirements. Refer to Figure 1.14-D
               Minimum Transparency                                                 See 135-7.1.7 for measurement information
           1*  per each Full Story & any Visible  12%                               and definition of blank wall limitations.
               Basement                                                             See 135-2.3.2 for window design.
               Principal Entrance Number    Minimum one per building                See Note 2 and Note 3 for 2- and 4-unit building
           1( Principal Entrance Location   Front street facade                     entrance requirements.
               Required Entrance
           2) Configuration                 Stoop or porch                          See 135-7.2 for definition of stoop and porch.

           2!  Permitted Roof Types         Low pitched                             See 135-1.17 for roof types
           2!  Street Facade Eave Height (ft)  1 story: maximum 8.5                 Measured from top of foundation to below
                                                                                    eave.
                                            1.5 to 2 story: maximum 16














                               1^
                                                                        2!


             1@ 1#            1$   1%     1&                               1*  typical



                                   1%      1&
                                                                                           1(2)







          Figure 1.14-C. House B: Height & uses Requirements             Figure 1.14-D.  House B: Facade Requirements



          CITY OF DES MOINES CHAPTER 135: PLANNING AND DESIGN DRAFT                                       135-1-55
   142   143   144   145   146   147   148   149   150   151   152