Page 155 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 155

DRAFT                                                            135-1. BUilDiNG tYPeS

                                                                                           House D Building Type



                                            N5               NX1              NX2, NX2a        NOTeS/ReFeReNCeS
           B.  Height. Refer to Figure 1.16-C
           1@  Minimum Overall Height       1.5 story        1.5 story        2 story
                                                                                               See 135-7.1.7 for measurement
           1#  Maximum Overall Height       2.5 stories      2.5 stories      2.5 stories      information.
                                                                                               Story heights are measured floor
                                                                                               to floor.
               All Full Stories: (Measured floor-to-floor)
           1$    Minimum Height (ft)        9                9                9
                 Maximum Height (ft)        12               12               12
           c.  Uses. Refer to Figure 1.16-C.
                                            Any permitted use;  any permitted use   any permitted use   See Chapter 134, Article 3 for
                                            N5-2 district allows up   except multiple family   except multiple family   permitted uses per zoning
           1%  All Stories                  to 2 units;      is limited to no more   is limited to no more   district and definition of uses.
                                            N5-4 district allows up   than 4 units  than 6 units  See Note 4 for multiple-unit
                                            to 4 units                                         buildings, where permitted.
           1^  Required Occupied Space      minimum 20-foot depth on all full floors on front facade  See 135-7.2 for definition of
                                                                                               occupied space.
               Parking within Principal                                                        Refer to occupied space
           1& Building                      fully in the basement or in the rear of the ground story  requirement above.
           D. Street Facade & roof requirements. Refer to Figure 1.16-D
               Minimum Transparency         15%; blank wall   18%; blank wall   18%; blank wall   See 135-7.1.7 for measurement
           1*  per each Full Story & any Visible  limitations apply to   limitations apply to   limitations apply to   information and definition of
                                                                              front and street side
               Basement                     front facade     front facade     facade           blank wall limitations.
               Principal Entrance Number    Minimum one per building                           See Note 4 for multiple-unit
           1( Principal Entrance Location   Front street facade                                buildings, where permitted.
               Required Entrance            Stoop, enclosed porch,                             See 135-7.2 for definition of
           2) Configuration                 or porch         Porch            Porch            stoop and porch.
               Specific Permitted Major                                                        See 135-2.2 for facade and roof
           2! Building Materials            Finished wood, brick, stone, fiber cement board    materials
               Permitted Roof Types         Pitched gable or hipped roof; low pitched on 2 story buildings; tower
           2@                               permitted                                          See 135-1.17 for roof types
               Minimum Eave Depth (in)      14
                                            On 1 and 1.5 story buildings, where the ridge line is parallel to the   See 135-7.2 for definition of
           2#  Dormers & Gables             street, at least one dormer or gable end is required for every 24 feet of   dormer.
                                            continuous ridgeline.






                                1^





                                   1%                                   2@                      2#
                                                                                       2#
              1#            1$    1%
              1@
                                                                                          2!
                             1$ 1%            1&                          2$                       typical  1*




                                                                                      1( 2)

          Figure 1.16-C. House D Building: Height & use Requirements  Figure 1.16-D. House D Building: Facade Requirements



          CITY OF DES MOINES CHAPTER 135: PLANNING AND DESIGN DRAFT                                       135-1-63
   150   151   152   153   154   155   156   157   158   159   160