Page 123 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 123

DRAFT                                                            135-1. BUilDiNG tYPeS

                                                                                               Commercial Center



                                            MX3                   CX                    NOTeS/ReFeReNCeS
           c.  Uses Refer to Figure 1.8-C
               Primary Frontage Facade      Permitted Commercial uses except Business and Trade School,
           1^  Ground Story   First 30 ft of depth along   and Office; Artisan Industrial; Wholesale Sales/Distribution   See Chapter 134, Article 3 for permitted
               frontage                     uses plus lobbies to upper story uses       uses per zoning district and definition of
                                                                                        uses..
               Non-Primary Frontage, All Upper
           1& Stories, & Basement           All permitted uses
           1*  Required Occupied Space      Minimum 20-foot depth on all full height floors of primary   See 135-7.2 for definition of occupied
                                            frontages
                                                                                        space.
               Parking/Loading within Principal                                         Refer to occupied space requirement
           1( Building                      Permitted fully in any basement and rear of all other stories  above.
           D. Street, Main Parking, & Public Way Facades and roof requirements Refer to Figure 1.8-D
               Minimum Primary Frontage &                                               See 135-7.1.7 for measurement
               Main Parking Lot Ground Story   65%, measured between 2 ft   60%, measured between 2 ft   information and the definition of
           2) Transparency                  and 8 ft; blank wall limitations   and 8 ft; blank wall limitations   transparency and blank wall limitations.
               Ground story requirements supersede   apply        apply                 See 135-7.2 for definition of main parking
               requirements per story, below.                                           lot.
               Minimum Transparency                                                     See 135-2.3.6 for principal entryway design
           2! per Each Story & any Half Story  20%                15%                   requirements
                                            minimum of one entrance per 45 ft of primary street and main  See 135-2.3.6 for principal entryway design
           2@  Entrance Location & Number   parking facade                              requirement. See 135-7.2 for definition of
                                                                                        main parking lot
               Primary Frontage Entryway(s)   recessed between 3’ and 8’ from the portion of the primary
           2# Configuration                 frontage facade closest to the street; maximum 8’ wide if
                                            outside the build-to zone
               Primary Frontage Entrance &   80% of entrances and the ground story shall be within 1.5’
           2$ Ground Story Elevation        vertically of adjacent sidewalk elevation
               Primary Frontage Ground Story                                            See 135-7.2 for definition of shadow line.
           2% Vertical Facade Divisions     one shadow line per every 30’ of facade width  See 135-2.3.9 for building articulation
                                                                                        requirements.
           2^  Horizontal Facade Divisions  one shadow line within 3’ of the top of the ground story  See 135-7.2 for definition of shadow line.
           2&  Permitted Roof Types         parapet, flat, pitched;                     See 135-1.17 for roof types.
                                            tower permitted







                                 1*                                   tower


                tower
                          1% 1&
                                                                      2&
                          1% 1&                   1(
                                                                      2!
                1@                                                    typical
                                                                                             2^

                   1!     1$                      1(
                              1^                                       2)

                                                                       2$

                              1&                  1(                          2@2#                2%  typical


            Figure 1.8-C. Commercial Center: Height & uses Requirements  Figure 1.8-D. Commercial Center: Facade Requirements



          CITY OF DES MOINES CHAPTER 135: PLANNING AND DESIGN DRAFT                                       135-1-31
   118   119   120   121   122   123   124   125   126   127   128