Page 120 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 120

135-1. BUilDiNG tYPeS                                                                             DRAFT

         General Building



         A.  General Building Notes
            1.  RX and EX to N District Transition. RX and EX
               district double frontage lots (see definition in
               135-7.2) that are deeper than 120 feet and share
               a primary frontage with an N district shall provide
               the following:
                a.  One or more of the following building types
                    shall front the adjacent N district primary
                    street:
                    i.   House permitted in the adjacent N
                        district.
                    ii.   Row or Flat building as permitted in
                        NX2.
                    iii.  General building as permitted but
                        limited to 3 stories a minimum of depth
                        of 30 feet into lot from the N district
                        primary frontage.
                b.  The RX or EX district lot shall incorporate an
                    interior alley, lane, or drive to provide access
                    to both building parking and the garage/
                    parking for the House, Row, or Flat building.
                c.  The rear of all buildings shall be fully
                    screened by building from both primary
                    streets.
            2.  Courtyards. One courtyard, maximum of 30%
               of facade width or 50 feet wide, whichever is
               less, may count towards the minimum primary
               frontage coverage.
            3.  Minimum Pedestrian Area. Along all streets
               where the area from the back of curb to the
               lot line is less than 12 feet, the build-to zone
               shall begin at 12 feet from the back of curb and
               extend into the site the depth defined.
            4.  Limited Side Yard Parking. Limited side
               yard parking means one double- or single-
               loaded aisle, with the centerline of the aisle
               perpendicular to the street, is permitted in the
               interior side yard. Maximum width of double-
               loaded is 60 feet and 40 feet for single-loaded,
               measured along the right-of-way. Parking may be
               angled or head-in. Frontage Buffer required per
               135-5.9.














         135-1-28                                                                         DRAFT AuGuST 3, 2017
   115   116   117   118   119   120   121   122   123   124   125