Page 119 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 119

DRAFT                                                            135-1. BUilDiNG tYPeS

                                                                                                  General Building



                                            RX1        RX2, P2    NX3        eX, I1, I2  NOTeS/ReFeReNCeS
           c.  Uses Refer to Figure 1.7-C
                                            Any permitted use except Commercial Service; Day Care;
                                            Eating and Drinking Places; Entertainment & Spectator Events;  See Chapter 134, Article 3 for permitted
           1$  All Stories & Basement       Retail Sales; Sports and Recreation, Participant; and Vehicle   uses per zoning district and definition of
                                            Sales and Service are limited to no more than 25% of the   uses..
                                            ground floor area
           1%  Required Occupied Space      Minimum 20-foot depth on all full height floors of primary   See 135-7.2 for definition of occupied
                                            frontages
                                                                                       space.
               Parking/Loading within Principal                                        Refer to occupied space requirement
           1^ Building                      Permitted fully in any basement and rear of all other stories  above.
           D. Street, Public Way, & courtyard Facades and roof requirements Refer to Figure 1.7-D
               Minimum Transparency                                                    See 135-7.1.7 for measurement
           1& per Each Story & any Half Story  18%; blank wall limitations apply       information and the definition of
                                                                                       transparency and blank wall limitations.
           1*  Entrance Location & Number   Principal entrance required on primary frontage facade;   See 135-2.3.6 for principal entryway design
                                            minimum of one per 100 ft of primary street facade
                                                                                       requirements
               Primary Frontage Entryway(s)                                            See 135-2.3.6 for principal entryway design
           1( Configuration                 Entry doors shall be off a stoop, minimum 6’ wide and 3’ deep  requirements
                                            At least 80% of entrances and the ground story shall be within
               Primary Frontage Entrance &   30 inches vertically of adjacent sidewalk elevation OR between
           2) Ground Story Elevation        30 inches and 5 feet with visible basement (transparency
                                            required)
               Primary Frontage Ground Story                                           See 135-7.2 for definition of shadow line.
           2! Vertical Facade Divisions     At least one shadow line per every 120’  of facade width  See 135-2.3.9 for building articulation
                                                                                       requirements.
                                            At least one shadow line within 3’ of the any story line between
           2@  Horizontal Facade Divisions  1st and 3rd story;                         See 135-7.2 for definition of shadow line.
                                            For buildings over 5 stories: minimum of one shadow line
                                            within 3’ of any story between 3rd and 6th story
           2#  Permitted Roof Types         Parapet, flat, pitched;                    See 135-1.17 for roof types.
                                            tower permitted













                                        1%
                                                                           2#

                          1@         1#    1$          1^
                                     1#    1$          1^                 1&
                                                                         typical
                                     1# 1$             1^
                                                                                                2^
                             1!       1# 1$            1^                             2!
                       2)                                                 2)              2@
                                               1$1^
                                                                                 1*1(



            Figure 1.7-C. General Building: Height & uses Requirements  Figure 1.7-D. General Building: Facade Requirements



          CITY OF DES MOINES CHAPTER 135: PLANNING AND DESIGN DRAFT                                       135-1-27
   114   115   116   117   118   119   120   121   122   123   124