Page 115 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 115

DRAFT                                                            135-1. BUilDiNG tYPeS

                                                                                             Commercial Cottage



                                            MX1            MX3           RX1, eX       NOTeS/ReFeReNCeS
           c.  Uses Refer to Figure 1.6-C
               Primary Frontage Facade
           1$  Ground Story   First 30 ft of depth along   Any permitted use category except residential  See Chapter 134, Article 3 for permitted
               frontage                                                                uses per zoning district and definition of
               Non-Primary Frontage, All Upper                                         uses..
           1% Stories, & Basement           Any permitted use
           1^  Required Occupied Space      Minimum 20-foot depth on all full height floors of primary   See 135-7.2 for definition of occupied
                                            frontages
                                                                                       space.
               Parking/Loading within Principal                                        Refer to occupied space requirement
           1& Building                      Not permitted                              above.
           D. Street & Public Way Facades and roof requirements Refer to Figure 1.6-D
               Minimum Primary Frontage     55%, measured   45%, measured
           1*  Ground Story Transparency    between 2 ft and   between 2 ft and   15%; blank wall   See 135-7.1.7 for measurement
                                            8 ft; blank wall
                                                                         limitations apply
                                                           8 ft; blank wall
               Ground story requirements supersede
               requirements per story, below.  limitations apply  limitations apply    information and the definition of
                                                                                       transparency and blank wall limitations.
               Minimum Transparency
           1( per Each Story & any Half Story  15%; blank wall limitations apply
           2)  Entrance Location & Number   Principal entrance required on primary frontage facade  See  135-2.3.6 for principal entryway
                                                                                       design requirements
               Primary Frontage Entryway(s)   Entrance must transition from the sidewalk via a stoop,   See  135-2.3.6 for principal entryway
                                                                                       design requirements
           2! Configuration                 minimum 4 ft deep by 4 ft wide, or a porch, minimum 6 ft   See 135-7.2 for definition of stoop and
                                            deep by 6 ft wide                          porch.
               Primary Frontage Entrance &   Ground story shall be within 30 inches vertically of adjacent   See 135-7.2 for definition of visible
           2@ Ground Story Elevation        sidewalk elevation OR between 30 inches and 5 feet with   basement.
                                            visible basement (transparency required)
               Primary Frontage Ground Story                                           See 135-7.2 for definition of shadow line.
           2# Vertical Facade Divisions     None required
           2$  Horizontal Facade Divisions  None required                              See 135-7.2 for definition of shadow line.
           2%  Permitted Roof Types         Pitched only                               See 135-1.17 for roof types.











                      1^



                                                                           2%
                    1# 1%

      1@            1# 1%                                                  1(
          1!                                                              typical
                    1# 1$                                                  1*
                                                                           2@
                         1%                                                                    2)2!





            Figure 1.6-C. Commercial Cottage: Height & uses Requirements  Figure 1.6-D.  Commercial Cottage: Facade Requirements



          CITY OF DES MOINES CHAPTER 135: PLANNING AND DESIGN DRAFT                                       135-1-23
   110   111   112   113   114   115   116   117   118   119   120