Page 111 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 111

DRAFT                                                            135-1. BUilDiNG tYPeS

                                                                                                        Storefront

                                          MX1          MX2         MX3          CX         NOTeS/ReFeReNCeS
           c.  Uses Refer to Figure 1.5-C
                                                                   Permitted Public, Civic, and
                                          Permitted Public, Civic, and   Institutional uses; Commercial
               Primary Frontage Facade    Institutional uses; Commercial uses  uses except Business and Trade   See Chapter 134, Article 3 for permitted
           1^  Ground Story   First 30 ft of depth   except Business and Trade School,  School, and Office; Artisan   uses per zoning district and definition
               along frontage             and Office; Artisan Industrial; and   Industrial; Wholesale Sales/  of uses..
                                          lobbies to upper story uses  Distribution; and lobbies to upper
                                                                   story uses
               Non-Primary Frontage, All                                                   See Chapter 134, Article 3 for permitted
           1& Upper Stories, & Basement   Any permitted use                                uses per zoning district and definition
                                                                                           of uses..
           1*  Required Occupied Space    Minimum 30-foot depth on all full height floors of primary frontages  See 135-7.2 for definition of occupied
                                                                                           space.
               Parking/Loading within                                                      Refer to occupied space requirement
           1( Principal Building          Permitted fully in any basement and rear of all other stories  above.
           D. Street & Public Way Facades and roof requirements Refer to Figure 1.5-D
               Minimum Primary Frontage   65%, measured   70%, measured   65%, measured   60%, measured
                                                                                between 2 ft
                                                       between 2 ft
           2)  Ground Story Transparency   between 2 ft and   and 10 ft; blank   between 2 ft and   and 8 ft; blank   See 135-7.1.7 for measurement
                                                                   8 ft; blank wall
                                          8 ft; blank wall
               Ground story requirements supersede
                                                                                           information and the definition of
               requirements per story, below.  limitations apply  wall limitations   limitations apply  wall limitations   transparency and blank wall limitations.
                                                       apply                    apply
               Minimum Transparency                                                        See Note 4. for requirements at
                                                                                           corners.
           2!  per Each Story & any Half   15%; blank wall limitations apply
               Story
                                          Principal entrance required on primary frontage facade; minimum of
           2@  Entrance Location & Number  one per 45 ft of primary street facade; lobby entrance for upper story   See  135-2.3.6 for principal entryway
                                                                                           design requirements
                                          uses shall be located on a public way
               Primary Frontage Entryway(s)   Recessed between 3’ and 8’ from the portion of   No   See  135-2.3.6 for principal entryway
           2# Configuration               the  primary frontage facade closest to the street;   requirements  design requirements
                                          maximum 8’ wide if outside the build-to zone
               Primary Frontage Entrance &   At least 80% of entrances and the ground story shall be within 1.5’
           2$ Ground Story Elevation      vertically of adjacent sidewalk elevation
               Primary Frontage Ground                                                     See 135-7.2 for definition of shadow
           2%  Story Vertical Facade      At least one shadow line per every 30’ of facade width  line. See 135-2.3.9 for building
               Divisions                                                                   articulation requirements.
                                          At least one shadow line within 3’ of the top of the ground story;   See 135-7.2 for definition of shadow
           2^  Horizontal Facade Divisions  For buildings over 5 stories: minimum of one shadow line within 3’ of   line.
                                          any story between the 3rd and 5th story
           2&  Permitted Roof Types       Parapet, flat;                                   See 135-1.17 for roof types.
                                          tower permitted
                            1*
                tower                                                tower
                         1&
                                                                      2&
                       1%      1&            1(
                       1%      1&            1(                       2!            2^
               1@                                                     typical
                       1%      1&            1(
                                                                                       2^
                  1!
                       1$      1^            1(                       2)

                                                                      2$
                               1&            1(                              2@2#            2%  typical



           Figure 1.5-C. Storefront: Height & uses Requirements   Figure 1.5-D.  Storefront: Facade Requirements



          CITY OF DES MOINES CHAPTER 135: PLANNING AND DESIGN DRAFT                                       135-1-19
   106   107   108   109   110   111   112   113   114   115   116