Page 56 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 56

134-5. SiGNS                                                                                      DRAFT

         Nonconforming Signs


               of largest sign face is the area of the sign (see   B.  Nits. For the purpose of verifying compliance with
               Figure 5.10-I).                                     maximum brightness level limits expressed in nits
            4.  Non-planar Signs                                   (candelas per square meter), brightness levels must
               Spherical, free-form, sculptural or other non-      be measured with the dynamic display set to run full
               planar sign area is measured as 50% of the sum      white copy with a luminance meter positioned at a
               of the areas using only the 4 vertical sides of the   location perpendicular to the sign face center. When
               smallest 4-sided polyhedron that will encompass     taking the luminance reading, the sign face must be
               the sign structure. Signs with greater than 4       the only subject visible in the viewfinder.
                                                                5.9.5   WiNDOW AreA
                                                                The area of a window includes only the glass or glazed
                                                                elements of the window. Frames, mullions and similar
                                                                features are not counted as part of the window area
                                                                (see Figure 5.10-N).








         Figure 5.10-L.  Area of Non-Planar Sign
               polyhedron faces are prohibited (see Figure
               5.10-L).
         5.9.2   SiGN HeiGHt
         The height of a sign is measured as the vertical distance


                                                                    Figure 5.10-N.  Window Area


                                                                134-5.10  Nonconforming Signs

                                                                See section 134-7.6.
             Figure 5.10-M.  Sign Height


         from ground level at the base of the sign to the highest
         point of the sign (see Figure 5.10-M).

         5.9.3   SetBAcK, SPAciNG AND SePArAtiON
         DiStANceS
         unless otherwise expressly stated, required setback,
         spacing and separation distances between signs must
         be measured in a straight line from the nearest points
         on the respective signs or sign structures. Required
         separation distances between signs and zoning
         districts, area or lots must be measured in a straight
         line from the nearest point on the sign structure to the
         nearest point of the subject district, area or lot.

         5.9.4   illUMiNAtiON AND lUMiNANce
         A.  Foot-candles. Sign illumination in foot-candles is
            measured 2 feet from the sign face.




         134-5-14                                                                         DRAFT AuguST 3, 2017
   51   52   53   54   55   56   57   58   59   60   61