Page 135 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 135

DRAFT                                                            135-1. BUilDiNG tYPeS

                                                                                                 Flat Building Type



                                            NX2, NX2a        RX1             RX2, DXR, NX3      NOTeS/ReFeReNCeS
           B.  Height. Refer to Figure 1.11-C

           1#  Minimum Overall Height       2 story          2 story         3 story

                                            3.5 stories; up to 5.5   3.5 stories; up to   5.5 stories; up to 10   See 135-7.1.7 for
                                                             5.5 stories by type 2
           1$  Maximum Overall Height       stories by type 2 design   design exception per   stories by type 2 design   measurement information.
                                                                                                Story heights are measured
                                            exception per 135-6.2  135-6.2   exception per 135-6.2  floor to floor.
               All Full Stories: (Measured floor-to-floor)
           1%    Minimum Height (ft)        9                9               9
                 Maximum Height (ft)        12               12              14
           c.  Uses. Refer to Figure 1.11-C
                                                                                                See Chapter 134, Article 3 for
           1^  All Stories                  Any permitted use                                   permitted uses per zoning
                                                                                                district and definition of uses.
           1&  Required Occupied Space      Minimum 20-foot depth on all full height floors of primary frontages  See 135-7.2 for definition of
                                                                                                occupied space.
               Parking within Principal                                                         Refer to occupied space
           1* Building                      Permitted fully in any basement and rear of all other stories  requirement above.

           D. Street Facades & roof requirements. Refer to Figure 1.11-D
               Minimum Transparency                                                             See 135-7.1.7 for
           1(  per each Full Story & any Visible   15%; blank wall   20%; blank wall limitations apply  measurement information
                                            limitations apply
                                                                                                and definition of blank wall
               Basement                                                                         limitations.
               Principal Entrance Number    Minimum one per 90 feet of building facade          See 135-2.3.6 for principal
           2) Principal Entrance Location   Front street facade                                 entryway design requirement.
               Required Entrance            Stoop or porch                   Stoop or porch
           2!  Configuration                Between 0 and 4.5 feet above public sidewalk  Between 2.5 and 6 feet   See 135-7.2 for definition of
                                                                                                stoop and porch.
               Entrance Elevation                                            above public sidewalk
           2@  Horizontal Facade Divisions  At least one shadow line within 3 feet of the top of the ground story or any   See 135-7.2 for definition of
                                                                                                shadow line
                                            visible basement
           2#  Vertical Facade Divisions    A change in facade plane of at least 12 inches deep required for every 70
                                            feet of front facade
               Specific Permitted Major                                                         See 135-2.2 for facade and
           2$ Building Materials            Brick, stone                                        roof materials
           2%  Permitted Roof Types         Parapet, low pitched, pitched roof, flat; Tower permitted  See 135-1.17 for roof types


                             1&
                                                                                2%
             tower                                                     tower
                         1%
                                                                       2%
                         1%       1^         1*
            1$                                                          2$           2#

                         1%       1^         1*
               1#                                                                           2@
                          1%      1^         1*                                                    typical  1(
                                                                        2!


                                        1*                                     2) 2!

           Figure 1.11-C.  Flat Building: Height & use Requirements.  Figure 1.11-D. Flat Building: Facade Requirements.



          CITY OF DES MOINES CHAPTER 135: PLANNING AND DESIGN DRAFT                                       135-1-43