Page 165 - Des Moines - Zoning, Planning and Design Ch 134, 135
P. 165

DRAFT                                                            135-1. BUilDiNG tYPeS

                                                                                             Accessory Structures


                the rear of the building, fully screened by the        b.  All Other Districts. The maximum height is
                building from the primary street, except in MX-3,          60 feet.
                the drive-through is permitted on the interior     3.  Setback. A setback of 10 feet from all lot lines is
                side of the building.                                  required.
            2.  Stacking. Stacking of cars shall be accommodated   4.  Flag Size. The dimensions of any flag shall be
                in the rear or interior side yard.                     proportional to the flagpole height such that the
            3.  Accessory Structures/Signs. The menu board and         hoist side of the flag shall not exceed 50 percent
                speaker shall be located in the rear or interior       of the vertical height.
                side yard                                          5.  Quantity of Flagpoles.  No more than 2 flagpoles
                                                                                          3
            4.  Where the rear of the lot abuts an N district, the     are permitted on a residential lot.
                drive-through facility shall be located a minimum   F.  Fueling Stations and car Washes. Refer to 134-
                of 70 feet from the rear lot line. A side and rear   3.5.18.A and Table 3.1-1 for fueling stations and car
                buffer per 135-5.10 is required.                    wash uses. All fueling stations and car washes shall
            5.  Drive-through canopies and roofs shall match        meet the following requirements. Refer to Figure
                the roof of the principal building. Materials used   1.19-D for one illustration of a compliant fueling
                for the drive through supports or other features    station.
                shall be repeated from the principal building      1.  Location of Pumps. Any fueling pumps shall be
                design.                                                located in the rear or interior side yard.
          e.  Flag Pole. A freestanding pole, usually constructed   3 Revisit the allowance of 2 flagpoles on a residential lot.
             of wood or metal,
            1.  Yard. Permitted in all yards.
            2.  Height. A flag pole shall not exceed the following
                height limits:
                 a.  MX1, RX1, N, NX Districts. The maximum
                    height is 15 feet



                                                                                Rear Lot Line
                     alley










                                                                                      Drive-
                                                                                      Through
                                       Principal
                                                                                      Canopy
                Secondary Street  corner lot line  Deck or    Structure  non-primary street  Building
                          Patio
                                                                                   Footprint


                                                                              Front Lot Line
                                     Front lot Line                       Primary Street
                         Max 30%
                                Primary Street
                          Required Front Property Coverage
           Figure 1.19-B.  Deck and Patio for Non-Residential use  Figure 1.19-C.  Example of Drive-Through Facility Layout.



          CITY OF DES MOINES CHAPTER 135: PLANNING AND DESIGN DRAFT                                       135-1-73
   160   161   162   163   164   165   166   167   168   169   170